Skip Link Hidden Text

Biological Indicators for Sterilization

Biological indicators (BIs) provide information on whether necessary conditions were met to kill a specified number of microorganisms (bacterial spores) for a given sterilization process, such as Vaporized Hydrogen Peroxide (VH2O2) sterilization in V-PRO Low Temperature Sterilizers.

BIs are typically used within process challenge devices (PCD), designed to represent the most challenging products routinely processed for autoclave sterilization testing. A passing result for the BI within the PCD demonstrates that the sterilization cycle was effective at inactivating the BI, providing Sterile Processing Department staff with a level of assurance in their sterilization process.

Steam Sterilization

Celerity 20 Steam BI
Celerity™ 20 STEAM Biological Indicator
  • Fast 20-minute results for load monitoring
  • Easy to use twist and flick activation means no separate activator is needed
  • Integrated barcode label makes electronic documentation easy
  • This product is registered with the Malaysian Medical Device Authority (MDA) under Registration No. GA3261323-155241 in accordance with the Medical Device Act 2012 (Act 737) and its subsidiary regulations
Celerity 20 STEAM Process Challenge Device
Celerity™ 20 STEAM Process Challenge Device
  • Fast 20-minute results for load monitoring
  • Compact process challenge device for easy testing and quick interpretation
  • Validated for either dynamic air removal or gravity steam sterilization cycles
  • This product is registered with the Malaysian Medical Device Authority (MDA) under Registration No. GA3261323-155241 in accordance with the Medical Device Act 2012 (Act 737) and its subsidiary regulations

VH2O2 Sterilization

Celerity 20 HP Biological Indicator
Celerity™ 20 HP Biological Indicators
  • Read Time: Celerity 20 HP Biological Indicator provides results in 20 minutes
  • Cycles: Single-use, rapid readout biological indicator for use with V-PRO™ Low Temperature Sterilization Systems and STERRAD Systems*
  • Features: Innovative glass-free design, requiring no separate activator
  • This product is registered with the Malaysian Medical Device Authority (MDA) under Registration No. GA6370624-168962 in accordance with the Medical Device Act 2012 (Act 737) and its subsidiary regulations
Celerity 20 HP Challenge Indicator
Celerity™ 20 HP Challenge Pack
  • Read Time: Provides biological indicator results in 20 minutes
  • Cycles: Used for qualification of V-PRO™ Low Temperature Sterilizers in less than three hours
  • Feature: Challenge pack includes a Celerity™ HP Biological Indicator, a chemical indicator strip, and a blue polyurethane foam sheet
  • This product is registered with the Malaysian Medical Device Authority (MDA) under Registration No. GA6370624-168962 in accordance with the Medical Device Act 2012 (Act 737) and its subsidiary regulations

Incubators

Celerity Incubator
Celerity™ Incubator
  • Universal incubator for use with both Celerity™ STEAM and VH2O2 Biological Indicators
  • Compact design requires minimal workspace while holding up to eight biological indicators
  • Connectivity allows for electronic record-keeping and integration with tracking systems
  • This product is registered with the Malaysian Medical Device Authority (MDA) under Registration No. GA3314323-155211 in accordance with the Medical Device Act 2012 (Act 737) and its subsidiary regulations